Eyenet Camera System

From REALab Wiki
Revision as of 20:30, 6 December 2012 by Barvision (talk | contribs) (→‎installing mx software)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

The eyenet surveillance camera system offers discrete yet high spatial and temporal resolution video recording, and can be controlled both locally and remotely.

installing mx software

There's software for both windows (mx control center) and macs (mx easy). We have a dropbox link to this software in case you would like to install it on additional computers. This software can be used on any computer plugged in to the UBC network, or remotely using VPN. Below describes the setup for mxcontrol.

install individual camera boards (3 boards x 2 cameras/board = 6 cameras), using the common ip address and unique port, as well as the user name and password

  • video source > add
  • insert manually > camera

then set up the layout for the 6 cameras in pairs (3 boards)

  • layout > new > auto grid
  • edit grids
  • adjust pixel with, change according to the legend for e.g., panoramic mode, then save
  • then drag camera pairs over to open slot on the layout

note: remember to "save configuration" when exiting mx control center

q: can you have only one of the two cameras for a given board in your layout? a: you need to display both if you want to record both

Hardware Setup/Camera Positioning

The bulk of the hardware is situated in room 3008B. The 2 ceiling cameras in RR2 are pretty well set in there, but the 2 boards of 4 loose cameras can be easily moved into any of the following rooms: RR1, RR2, 3008B, 3008C, and 3008D. For example, in order to plug the 2 boards (4 cameras) into Room 3008C:

1) In Room 3008B, plug the 2 green ethernet cables (not the one for the ceiling cameras in 3008) into slots 1 and 2 in the panel labelled Rm. 3008C:

Eyenet hardware.png



2) Next, in Room 3008C, plug the ethernet cables from the 2 boards into slots 1 and 2 in the panel labelled Rm. 3008B:

Eyenet hardware2.png


You can similarly switch up the cables to connect the hardware in 3008B with the cameras in any of the other rooms (RR1, RR2, 3008C, 3008D), or just plug the ethernet cables from the 2 boards of 4 cameras straight into the hardware in 3008B (if you want to use the cameras in there). Note that when you plug the cables in, it will take about 30 seconds for the power to start flowing to the cameras and thus for the cameras' feeds to show up in the software: once the yellow light on the left of the PoE board lights up, you should have power to that camera and it should show up in the software.


note: when the cameras are not in use, they should be placed in the small wooden filing cabinet in room 3008B, near the rest of the hardware

PDF Manuals

MxEasy Manual